Available in RS485 output (with custom protocols available upon request), the new 226-10-010 Series can communicate over very long transmission lines, eliminating the need for A/D conversion. Rated at 0.5% of full scale, the 226-10-010 Series provides the accuracy, performance and reliability needed for remote pressure and temperature measurement.
The 226-10-010 Series is temperature compensated and provides input/output isolation, circuit interface, input reverse polarity protection and output short circuit protection. Offered in a manifold style mounting package, the 226-10-010 Series can also be supplied with pressure adapters and mating connectors for increased installation flexibility and positioning.
Features:
•Operating Temperature: -40°F to +250°F (-40°C to +121°C)
•Accuracy of Digital Pressure Output: 0.5% of the full scale over the calibrated temperature range.
•Easy to Program & Interface.
•Polled & Continuous Output Operating Modes.
•Multi-Node Bus Environment Ready.
•Media Compatibility: Fluids and gases compatible with 304, 15-5 PH CRES and Buna-n-rubber.
•MIL-DTL-38999 Series Connection. Signal and power connections with exceptional sealing.
Typical Applications:
•Actuators
•Hydraulic Controls Systems.
•Industrial Process Equipment.
•Heavy Equipment / Off-Road Vehicle Hydraulic Monitoring.
•Test Stands & Testing Equipment.
The 226-10-010 Series can be provided with alternate port fittings to meet your specific requirements.