Compact rail mountable circuit breaker for plant and process control systems

2nd June 2008
Source: E-T-A
Posted By : ES Admin
Compact rail mountable circuit breaker for plant and process control systems
E-T-A Circuit Breakers has introduced a new rail-mountable, thermal-magnetic circuit breaker for the overcurrent protection of loads and their supply cables in plant and process control systems. It enables failures to be detected without delay to prevent personal injury as well as machinery from being damaged. Its small width of only 12.5mm gives it a competitive edge over standard products, which typically have widths of 17mm or even 22.5mm, enabling maximum exploitation of available space on a rail.
The toggle-action E-T-A 4220 circuit breaker has been designed for one- and two-phase applications for rated voltages of 240V AC/120V AC, three-phase up to 415V AC and for DC applications up to 80V. The single pole version of the E-T-A 4220 is available with a wide range of current ratings, from 0.1A to 32A, and with five different trip characteristics. This wide choice ensures precise matching for the application: not only to manage different start-up or continuous loads but also to cater for the size of cable cross section. Thus spurious disconnections, stoppages and downtimes are minimised. For two- or three-pole applications, individual poles with different ratings and different characteristics can be combined – offering a real competitive edge.

The type 4220 is offered with optional, integral auxiliary contacts (a make or break contact with physical isolation): this can signal circuit disconnection to a PLC, which will ensure rapid trouble shooting. As well as being able to wire the signal contacts individually, they can be interconnected quickly in parallel using a plug-in busbar (break contact). Small jumpers offer another connection possibility: they bridge two poles which are thus connected in series (make contact).

One of the 4220’s most striking features is its high rupture capacity in relation to its small width. Under test conditions, it reaches a short circuit interrupting capacity of 6000A to EN 60934 (circuit breakers for equipment protection) and 5000A to UL 489.

A sophisticated, plug-in type, power distribution busbar system for single pole line entry is also available. Two plastic slides at the side of the housing, which may be taken off if required, provide protection against brush contact during installation, normal operation and maintenance.

You must be logged in to comment

Write a comment

No comments




Sign up to view our publications

Sign up

Sign up to view our downloads

Sign up

The Magnetics Show US
22nd May 2024
United States of America The Pasadena Convention Center
2024 World Battery & Energy Storage Industry Expo (WBE)
8th August 2024
China 1st and 2nd Floor, Area A, China Import and Export Fair Complex