Blind via measurement in Si and GaAs

26th November 2008
Posted By : ES Admin
Blind via measurement in Si and GaAs
With semiconductor devices becoming smaller and smaller and between-level interconnects requiring the production of blind vias with high aspect ratios there is a need to be able to perform measurements on such features.
Armstrong Optical Ltd, in association with their supplier Precitec Optronik GmbH, have recently investigated the measurement of blind vias in silicon wafers. The vias were produced by laser drilling and had external hole diameters of between 15 and 30 microns and depths ranging from 50 to 500 microns.

By using the CHRocodile IT sensor system it was possible to measure both the external hole diameters and the depths of the blind vias, simultaneously, in a non-contact fashion with high accuracies.

The CHRocodile IT sensor system is one of a family of instruments available from Precitec Optronik GmbH that utilise the chromatic confocal sensor approach – the optical source being a broad spectral output device.

As the sensor probe is passive - having no power or electrical connection and at the end of an optical fibre that can be 30m in length - it is ideal for integration into production environments. The CHRocodile IT system operates at a 4KHz data collection rate and has been used to perform non-contact measurement tasks on silicon and GaAs wafers during grinding and on PV cells during manufacture.

You must be logged in to comment

Write a comment

No comments




Sign up to view our publications

Sign up

Sign up to view our downloads

Sign up

The Magnetics Show US
22nd May 2024
United States of America The Pasadena Convention Center
2024 World Battery & Energy Storage Industry Expo (WBE)
8th August 2024
China 1st and 2nd Floor, Area A, China Import and Export Fair Complex