FTIR gas analysis improves container safety

22nd February 2013
Posted By : ES Admin
FTIR gas analysis improves container safety
Entry to freight containers represents a significant hazard to staff responsible for inspection, stuffing or destuffing because of the large number of airborne chemicals that can be present. Research in Germany and the Netherlands found hazardous levels of gases and vapours in around 20% of all containers and this level of contamination is now accepted as commonplace.
It is therefore necessary to examine containers before entry and this work is usually conducted with a wide variety of gas detection techniques in order to be able to assess, individually, all of the substances of greatest concern. However, a Dutch firm of health and safety consultants, Reaktie, has employed FTIR (Fourier Transform Infra Red) gas analysis to dramatically improve the speed and effectiveness with which containers are assessed, because this technology enables the simultaneous measurement of the 50 gases of most concern.

Chemical Hazards
There are two potential sources of hazardous chemicals inside cargo containers; fumigants and chemicals that arise from the goods or packing materials.

Fumigants are applied to goods to control pests and micro-organisms. Cargoes most likely to have been fumigated include foodstuffs, leather goods, handicrafts, textiles, timber or cane furniture, luxury vehicles and cargo in timber cases or on timber pallets from Asia.

According to the IMO's international regulations, ‘Recommendations on the safe use of pesticides in ships’, fumigated containers and ship cargoes must be labelled giving specifications about dates of fumigation and the fumigation gas used. Furthermore, appropriate certificates are necessary and these records have to be forwarded to the Port Health Authorities without their explicitly asking for them. However, absence of marking cannot be taken to mean fumigants are not present. Containers marked as having been ventilated after fumigation may also contain fumigant that was absorbed by the cargo and released during transit. There is also concern that fumigants may be retained in the goods and subsequently present a hazard to logistics providers, retail staff and consumers.

Common fumigants include Chloropicrine, Methyl bromide, Ethylene dibromide, Sulfuryl fluoride and Phospine. However, with over 20 years of experience testing gases in containers, Peter Broersma from Reakti says “While the fumigants are highly toxic, the number of containers exceeding occupational exposure limits (OEL) due to other chemicals is much greater and the number of ‘failed’ containers is likely to rise as more containers are tested, detection methods improve and new gases are identified.”

Containers often travel for extended periods and experience a wide range of temperatures. It is therefore not surprising that unsafe levels of gases should accumulate in the confined space of a container. Peter identifies the typical sources of gases over their OELs as follows:

• Solvents from glues used to produce clothing, accessories and shoes
• 1,2, dichloroethane from plastic products, PVC, blister packaging etc.
• Formaldehyde found in cheap furniture (Plywood,MDF etc.) but also in used pallets and lashing materials
• Solvents and formaldehyde from poly-resin products
• Carbon monoxide from charcoal and natural products
• Carbon dioxide from natural products
• Ethylene oxide from medical equipment sterilised with ethylene oxide
• Solvents including Benzene, Toluene, Ethylbenzene and Xylene (BTEX) in Christmas and decoration products
• Flammable gases from disposable lighters
• Ammonia in household equipment with Bakelite parts
• Volatile Organic Compounds from fire blocks
• Pentanes and hexanes from consumer electronics
• Phosphine/arsine from natural minerals such as ferrosilicon

Inspection procedures
Major ports have strict regulations in place to protect against potential hazards in cargo containers. In general terms, every incoming stream of products has to be checked for dangerous gases and if one of more gases are detected during the preliminary investigation, all of the containers from this specific producer must be checked. If no gases are detected, it may be possible to only conduct random tests a few times per year. If it is necessary for Customs staff to enter a container, all containers must first be tested and if necessary de-gassed.

Gas detection
Since there are a large number of gases that might be present inside a container, the traditional approach to monitoring has been either to employ a wide range of instruments or to use chemical stain tubes for the most common gases, or a combination of both.

Chemical stain tubes provide a colorimetric assessment of an individual gas, typically with an accuracy of +/- 15%. Different tubes are available for many gases and results can be obtained between 5 seconds and 15 minutes depending on the test. Once a result has been obtained, the tube itself is hazardous waste and must be disposed of. Historically stain tubes have been popular because the cost per test is low. However, the number of tubes that have to be employed in order to demonstrate that a container is safe can be prohibitively expensive and time-consuming to employ.

Instrumental gas analyzers such as electrochemical sensors, that measure either a single gas or a small number of gases impart a similar level of risk to stain tubes because of the possibility of missing or failing to measure a harmful gas. Deploying multiple instruments also presents practical problems because each will require maintenance and re-calibration in addition to a power source or re-charging. Nevertheless, Reaktie for example, would normally conduct a preliminary assessment with a PID gas detector for total VOCs; an LEL combustible gas sensor and handheld electrochemical sensors might be employed for toxic gases such as carbon monoxide, phosphine, ammonia and ethylene oxide. An FTIR analyser would then be employed to measure 50 target gases simultaneously in a test that would take approximately 3 minutes. This ability to measure compounds individually is important because, for example, whilst a PID gas detector measures total VOCs, it does not provide an individual value for, say, benzene, which is a known carcinogen.

One of the potential problems with electrochemical sensors is their inability to cope with high concentrations in a sample gas. This can result in poisoning of the cell, which would normally result in instrument failure. In contrast, similar high concentrations do not harm FTIR, and the instrument can recommence analysis after a few minutes of backflushing.

Peter Broersma has been one of the first to utilise FTIR in the assessment of containers since it first became possible to acquire the technology in a portable battery powered unit. He says “The problems with hazardous gases in cargo containers is now widely publicised and the requirement for testing is growing as employers fulfil their responsibility to protect the health and welfare of staff. However, the traditional testing methods are laborious, time-consuming and risk failing to find a potentially harmful gas.

“FTIR has long been established as an accurate technology for the simultaneous measurement of gaseous emissions from industrial processes, so when the Finnish company Gasmet developed a portable version we were very eager to investigate its feasibility in container testing.

“Following our initial tests, we worked with Gasmet to develop a configuration for the portable FTIR (a Gasmet DX4030) that would measure the 50 compounds of greatest concern. As a result, we are now able to test for all of these gases in around 3 minutes, which dramatically lowers the time taken for container inspection and greatly increases the number of containers that can be examined every day.

“A further major advantage of this technology is the minimal amount of calibration and maintenance that is necessary. A new instrument can be delivered pre-configured and factory calibrated and from then on the only calibration required is a quick zero check with nitrogen once or twice per day. As a result, it is not necessary to transport a large number of expensive, bulky calibration bottles.

You must be logged in to comment

Write a comment

No comments




Sign up to view our publications

Sign up

Sign up to view our downloads

Sign up

The Magnetics Show US
22nd May 2024
United States of America The Pasadena Convention Center
2024 World Battery & Energy Storage Industry Expo (WBE)
8th August 2024
China 1st and 2nd Floor, Area A, China Import and Export Fair Complex