Gassonic Observer-H Ultrasonic Gas Leak Detector Features HART Communications Protocol

20th April 2012
Posted By : ES Admin
Gassonic Observer-H Ultrasonic Gas Leak Detector Features HART Communications Protocol
The Gassonic Observer-H Ultrasonic Gas Leak Detector from General Monitors is ideal for gas leak detection in pressurized systems. The new Gassonic Observer-H features HART communications, Modbus with single and block transfer modes, Emerson AMS Intelligent Device Manager support, and event logging. The Observer-H is ATEX, IECEx, FM and CSA hazardous area certified and SIL 3 suitable.
The Gassonic Observer-H detects gas leaks by sensing the airborne ultrasound emitted from leaking gas at high pressure. It is suitable for gas detection in open, well-ventilated areas, where traditional detection methods may be unsuitable or dependent on ventilation. Since the gas leak detector responds to the source of a gas release rather than the dispersed gas, it is unaffected by changing wind directions, gas dilution, and the direction of the leak. The Gassonic Observer-H’s wide coverage zone makes it possible to supervise areas up to a 20 meter radius, for the detection of leaks as small as 0.1 kg/sec., with only one device.

Rugged and designed for failsafe operation, the Gassonic Observer-H features robust microphone technology with an advanced stainlesssteel microphone. The detector also offers the Senssonic integrated acoustic self-test, which verifies the integrity of the instrument’s electric circuit and microphone every 15 minutes. It features stainless steel, AISI 316L explosion-proof housing, offering corrosion resistance in the harshest environments.

The versatile Gassonic Observer-H can be configured with an analog output or Modbus or HART communications to provide complete status and control capability in the control room. The Modbus and HART data can also be used for predictive maintenance and to enable asset management and process improvement.

The Gassonic Observer-H detects leaks at a frequency range of 25-70 kHz at a dynamic range of 58-104 dB. Detection coverage varies from 13-20 m radius in very low noise areas (<58 dB), 9-12 m radius in low noise areas (<68 dB), to 5-8 m radius in high noise areas (<78 dB). Such distances are defined for a methane gas leak of 0.1 kg/s.

The Gassonic Observer-H operates at a temperature range of -40°F to 140°F (-40°C to 60°C) and at a humidity range of 10 to 95% RH.

You must be logged in to comment

Write a comment

No comments




Sign up to view our publications

Sign up

Sign up to view our downloads

Sign up

GISEC Global
23rd April 2024
United Arab Emirates Halls 2-8 - Dubai World Trade Centre
The Magnetics Show US
22nd May 2024
United States of America The Pasadena Convention Center
2024 World Battery & Energy Storage Industry Expo (WBE)
8th August 2024
China 1st and 2nd Floor, Area A, China Import and Export Fair Complex